Single-Source
Responsibility
Means execution of a ready-to-use facility including basic rooms,
doors, ventilation systems, wave guide beyond cutoff filters, silencers,
alarm systems, and power and communication filters. Finishing options
include carpets, acoustic ceiling/wall coverings, computer floors,
weatherproofing, and other features. All available to provide a
complete functional security room complex fully tested and certified.
Custom Design
To suit specification requirements IAC's numerical control based
fabrication allows a wide range of flexibility to provide RF/acoustic
shielded security rooms to fit your spatial and other special requirements.
RF Shielding
Sentry rooms are electromagnetic shielded to 100dB at 10GHz and
fully satisfy "TEMPEST" level requirements.
Acoustic Shielding
Multi-Wave components are rated STC 52 exceeding the requirements
of DIAM 50-3 Sound Groups. In field noise reductions from NIC 48
to 75.
Physical Security
Sentry all-steel construction prevents unauthorized forced, or surreptitious
entry and fully satisfies DIAM 50-3 Sensitive Compartmented Information
Facility (SCIF) requirements.
Acoustic Requirements for SCIF Rooms
Please view our PDF on SCIF
requirements.
|
|
Modular
Construction
Sentry rooms are fully demountable and relocatable as programs
change without loss of acoustic or RF shielding effectiveness. Since
RF/acoustic and physical security is provided in a single perimeter
structure, re-location is easily accomplished.
Seismic Strength
Sentry rooms incorporate structural elements in the RF shell so
that seismic loads of Zone 4 magnitude are resisted without additional
external support structures.
Complete Weather Resistance
Sentry structures can handle wind loads as high as 120 miles per
hour (193 km/hr) and roof loads of 50 lbs/sq ft (2394 N/sq m) or
higher. With weather-resistance cladding they constitute esthetically
pleasing, free-standing buildings without the need for additional
conventional construction.
Tax Advantages
Sentry rooms are fully demountable and therefore qualify for accelerated
depreciation tax benefits. These savings significantly reduce the
cost of Sentry rooms when compared to welded-shell alternatives.
Savings can amount to as much as 25% of the purchase price. (Internal
Revenue Service Ruling 75-178)
Testing
All Sentry Multi-Wave shielded room components have been tested
for sound transmission loss, sound absorption, and radio frequency
attenuation to demonstrate compliance with NSA 65-6 TEMPEST and
DIAM 50-3 specifications in the fully equipped IAC laboratories
at engineering headquarters New York City. |